Add to cart

Commercial UV Sterilizers UVC

Product features:
  • 304 stainless steel reactor chamber in (S2Q-PA - S35)
  • 316L stainless steel reactor chamber in (S37 - S60)
  • Visual "power on"
  • Visual lamp life remaining
  • Audible lamp failure
  • audible lamp replacement reminder
  • Installation orientation vertical or horizontal (except for S37 & S60 vertical only)
  • Guaranteed the best market price
  • Excellent support 24 hours a day, 7 days a week
  • Refund in case of dissatisfaction
  • Originality of goods from top brands
  • Fast delivery in the shortest possible time

Price: Call us

تمامی کالاهای این فروشگاه اورجینال و برند بوده و با گارانتی بازگشت وجه ارائه می شوند. متن نمایش داده در تمامی محصولات و قابل تغییر از بخش تنظیمات پوسته می باشد.

ZamZam’s UVC systems virtually eliminate microbiological contaminants without using potentially hazardous chemicals. Water enters through the bottom port of the ultraviolet generator cell and swirls around a low pressure mercury vapor lamp, which emits powerful ultraviolet light energy at 235.7nm wave length. Bacteria, viruses and other micro-organisms absorb the light energy which disrupts their DNA, and are destroyed safely inside a factory tested stainless steel cell. The treated water then exits through the top port of the cell and is ready for consumption.

Benefits and Advantages of Commercial UV Sterilizers UVC:
  • Effective: Virtually all microorganisms are susceptible to UV disinfection
  • Automatic: Continuous or intermittent disinfection without special attention
  • Fast: Water is ready for consumption as soon as it leaves the cel
  • Easy: Simple installation and maintenance. Minimum space requirements
  • Safe: No danger or way of overdosing, no addition of hazardous chemicals
  • Economical: Hundreds of gallons of water can be purified for a few cents per day
  • No Chemicals: No chlorine taste or corrosion problems

How Effective are UV Sterilizers for Water Treatment?

UV water sterilizers are highly effective against all microbiological concerns, such as viruses and bacteria. Despite this, many microorganisms have greater resistance to UV light systems, which renders low-power UV sterilizers ineffective in eliminating these infectants. For this reason, we make sure to specifically design practicable UV water treatment systems to remove all unwanted microorganisms.

ZamZam actively engineers and manufactures thousands of commercial UV purification systems. Our engineering process is straightforward and designed to provide safe, and effective UV water sterilizers in quick fashion. This procedure allows for products that maintain regular, or irregular disinfection in the absence of significant attention or assessment. While our commercial UV systems require minimal maintenance, some types of upkeep are still necessary, such as:

Lamp Substitution

–   Unlike normal fluorescent lamps, Ultra Violet lamps do not sizzle out, and are instead solarized, which reduces heat energy by about 60% of a new lamp after one year of daily usage. For instance, new lamps can generate dosage levels over 55,000 µW-s/cm2. However, this level declines to about  30,000 µW-s/cm2, which is the minimum dosage required to adequately eliminate contaminants. When it falls below this level then it is time to replace the UV lamp. Side note, if you have a habit of regularly switching the lamp on and off then the life of the lamp will be shortened dramatically.

No Overheating

–  As with the case with other lamp types, the ultraviolet lamp units our engineers utilize have no chance of overheating. Therefore, the need for acquiring supplementary equipment to address issues of overheating is erased.

Cleaning the quartz sleeve

–   Cleaning your UV system becomes a necessity to prevent the accumulation of dirt around the quartz sleeve. Unclean ultraviolet sterilizers will inevitably lead to impassable quartz sleeves, and effectively hinder the UV rays from passing through the sleeve and into the water. To preserve sufficient purity, glass throughout the lamp must be cleaned on a regular basis. The frequency of cleaning is based on the quality of the water and will be advised to install a pretreatment such as media or cartridge filters.

Tracking Ultra Violet Dosage

–  Meters are used to ascertain the intensity of the UV light, and the degree of which the radiation is passing through the quartz sleeve. If the UV dosage is found to be too low then the disinfection process will be ineffective. It is also useful in specifying when the time for cleaning the quartz sleeve and replacing the UV lamp.

Questions & Answers

Should I filter my water before UV light disinfection?

–   Filtering water before entering it into a UV purification system is crucial since the clearer water increases the UV transmittance ratio. This means that the UV system will be able to transmit light waves with higher energy, which will penetrate the water more effectively and sterilize it. Consequently, it’s of utmost importance to monitor your UVT and observe its levels to keep it over the manufacturer’s minimum requirement for effective disinfection.

How to select the right UV system?

–   Every UV light system has pretreatment requirements, such as a certain level of turbidity, iron, hardness, and ultraviolet transmittance (UVT). Unclear water will result in a low ultraviolet transmittance, which reduces the effectiveness of disinfection, since the water will be less able to transmit ultraviolet light. To compensate for this issue, you will need a larger UV system with a higher flow rate. However, if your water is perfectly clear then the UVT percentage should be just fine.

Standard Features:

Available Options:

  • 304 stainless steel reactor chamber in (S2Q-PA – S35)
  • 316L stainless steel reactor chamber in (S37 – S60)
  • Visual “power on”
  • Visual lamp life remaining
  • Audible lamp failure
  • audible lamp replacement reminder
  • Installation orientation vertical or horizontal (except for S37 & S60 vertical only)
  • Dynamic flow restrictor
  • Temperature management valve (not available with S2Q-PA, S5Q-PA, S8Q-PA)
  • Solenoid valve
  • COMMcenter control package (available for S37 & S60 only)
  • Sensor reading output (4-20mA)
  • UV sensor
  • Cool touch fan
  • Flow meter

Subscribe to newsletter

Shopping Cart

No products in the cart.

Login to the site